Navigation

Arthroscopy and Sports Medicine

Joints connect bones to each other and provide the body with agility and stability. Obesity, misalignment, physical inactivity as well as sports injuries can lead to joint problems and restricted movement.

Many minimally invasive techniques can now be performed in joint surgery thanks to modern arthroscopy. The product range from KARL STORZ covers endoscopic instrument sets and implants for treatment of the shoulder, elbow, hip and knee joints as well as the wrist, interphalangeal and ankle joints.

In cooperation with renowned physicians, KARL STORZ was able to develop innovative products and techniques for, among others, meniscal refixation, cruciate ligament reconstruction, reconstruction of shoulder instability as well as hip arthroscopy.

Furthermore, KARL STORZ offers an appropriate portfolio of implants for arthroscopic reconstructive procedures. This segment includes both titanium and bioresorbable implants such as interference screws, suture anchors and fixation buttons.

Highlights

Diamond Standard: HOPKINS® Telescopes and Sheaths for Optimal Vision

KARL STORZ HOPKINS® telescopes are considered to be the best arthroscopes in the industry. The diverse product range covers all arthroscopic interventions while the unique rod lens system ensures excellent image quality with optimal brightness, contrast and detail properties.

The product range includes all well-established angles of view in arthroscopy:
• 0° • 30° • 70°

Arthroscopes with diameters ranging from 1 mm to 4 mm leave nothing to be desired. A selection of sheaths with various locking mechanisms, which are co-ordinated with HOPKINS® telescopes, ensures the safe locking of the telescope in the sheath.

EndoCAMeleon® with Variable Direction of View

A Revolution in Imaging

ENDOCAMELEON® ARTHRO is a multidirectional arthroscope that combines the existing HOPKINS® technology with a variable direction of view. This guarantees optimal image quality with ideal visualization. The desired direction of view can be adjusted between 15° and 90° during surgery.

Special Features:

  • HOPKINS® telescope with unique rod lens system for optimal brightness and contrast
  • Easy-to-use adjusting knob selects the desired direction of view (15° to 90°)
  • Better visualization of difficult-to-reach anatomical structures
  • Time-saving as portal changeover is reduced

ENDOMAT® SELECT – Meets Your Exact Requirements

ENDOMAT® SELECT for arthroscopy is a roller pump that regulates the irrigation of fluids according to the latest standards. ENDOMAT® SELECT for arthroscopy communicates effectively with the KARL STORZ shaver unit UNIDRIVE® S III Arthro. It also regulates the pressure and the flow rate to provide optimal imaging while maintaining joint distension. An optional feature is the BOOST mode that can be activated at any time. This provides temporary increase in pressure and irrigation inside the joint in order to stop bleeding.

ENDOMAT® SELECT has been designed as an interdisciplinary pump. Depending on individual preferences, the pump can be equipped with various software packages so that the unit can be used for either individual or multiple disciplines.

Benefits at a glance:

  • User-friendly interface and simple handling thanks to tubing set for single hand control
  • Rapid communication with the shaver unit
  • Safe use thanks to tubing set recognition
  • Seamless integration into existing systems
  • Optional software allows further applications to be added at any time

Additional information on the specialty

How to insert a telescope into a sheath

How to insert a telescope into a sheath

Media type:
Video, Product Film
Languages available:
D, E
Version:
2016
Material number:
959E
Specialties:
ENDOMAT® SELECT

ENDOMAT® SELECT

Media type:
Video, Product Film, Teaser
Languages available:
D, E
Version:
2016
Material number:
958E
Specialties:
AUTOCON® III 400 Teaser

AUTOCON® III 400 Teaser

Media type:
Video, Product Film
Languages available:
D, E
Version:
2016
Material number:
948E
Specialties:
Minimally Invasive Reconstruction of the Medial Patellofemoral Ligament (MPFL) Using a Quadriceps Tendon Graft

Minimally Invasive Reconstruction of the Medial Patellofemoral Ligament (MPFL) Using a Quadriceps Tendon Graft

Media type:
Doctor-to-doctor manuals
Languages available:
D, E
Version:
0.5 05-2016
Material number:
96155015E
Specialties:
Arthroscopy and Sports Medicine
Anatomic Reconstruction of the Anterior Cruciate Ligament – Quadriceps Tendon and Rectangular Bone Tunnels

Anatomic Reconstruction of the Anterior Cruciate Ligament – Quadriceps Tendon and Rectangular Bone Tunnels

Media type:
Doctor-to-doctor manuals
Languages available:
D, E
Version:
0.5 05-2016
Material number:
96155016E
Specialties:
Arthroscopy and Sports Medicine
Basic Instruments for Wrist Arthroscopy

Basic Instruments for Wrist Arthroscopy

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
1.1 09-2016
Material number:
96152060E
Specialties:
Arthroscopy and Sports Medicine
BioPlug 3.5 and 4.2 for the use in reconstructive surgery

BioPlug 3.5 and 4.2 for the use in reconstructive surgery

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT
Version:
16.1 09-2015
Material number:
96152023E
Specialties:
Arthroscopy and Sports Medicine
HPS – HIP PORTAL SYSTEM. PD Dr. med. Michael Dienst, Munich, Germany

HPS – HIP PORTAL SYSTEM. PD Dr. med. Michael Dienst, Munich, Germany

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
13.0 06-2016
Material number:
96152030E
Specialties:
Arthroscopy and Sports Medicine
SilCut® PRO and SilGrasp® PRO - Experience Meets Innovation

SilCut® PRO and SilGrasp® PRO - Experience Meets Innovation

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT, RU, JP
Version:
6.1 08-2016
Material number:
96152044E
Specialties:
Arthroscopy and Sports Medicine
Titanium Anchors 3.0 and 5.0/6.5 for use in reconstructive surgery

Titanium Anchors 3.0 and 5.0/6.5 for use in reconstructive surgery

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
11.1 08-2016
Material number:
96152035E
Specialties:
Arthroscopy and Sports Medicine
WONDERHOOK® Suture System

WONDERHOOK® Suture System

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT, RU, CN, AR, JP, TR
Version:
1.1 03-2016
Material number:
97000171
Specialties:
This document is only available for registered users. Please log in.
Packaging symbols

Packaging symbols

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
2.0. 07-2016
Material number:
96216316DF
Specialties:
This document is only available for registered users. Please log in.
Depth gauge, long Model 28729 TL

Depth gauge, long Model 28729 TL

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT, RU, CN, AR, JP, TR
Version:
1.0 05-2016
Material number:
97000105
Specialties:
This document is only available for registered users. Please log in.
Saw blades 28207 SLA ... SLH

Saw blades 28207 SLA ... SLH

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT
Version:
1.2 03-2016
Material number:
96156317DF
Specialties:
This document is only available for registered users. Please log in.
20530820 AUTOCON® II 80

20530820 AUTOCON® II 80

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
2.1 01-2016
Material number:
96206250D
Specialties:
This document is only available for registered users. Please log in.

Arthroscopic reconstruction of the anterolateral bundle of the posterior cruciate ligament in single-bundle technique with autologous hamstring grafts

Human Medicine

Arthroscopy and Sports Medicine

Petersen W, Zantop T.

Oper Orthop Traumatol. 2010 Oct;22(4):354-72.

Minimally Invasive Acromioclavicular Joint Reconstruction (MINAR)

Human Medicine

Arthroscopy and Sports Medicine

Petersen W, Wellmann M, Rosslenbroich S, Zantop T.

Oper Orthop Traumatol. 2010 Mar;22(1):52-61.

Standardized cartilage biopsies from the intercondylar notch for autologous chondrocyte implantation (ACI)

Human Medicine

Arthroscopy and Sports Medicine

Niemeyer P, Pestka JM, Kreuz PC, Salzmann GM, Köstler W, Südkamp NP, Steinwachs M.

Knee Surg Sports Traumatol Arthrosc. 2010 Aug;18(8):1122-7. Epub 2010 Mar 27.

Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique

Human Medicine

Arthroscopy and Sports Medicine

Lenschow S, Herbort M, Strässer A, Strobel M, Raschke M, Petersen W, Zantop T.

Arch Orthop Trauma Surg. 2011 Aug;131(8):1067-72. Epub 2011 Feb 18.