Navigation

MTP Single-Use Products

With the MTP Single-Use Products range, KARL STORZ combines the best from two fields of technology: reusable endoscopy products are specifically complemented by MTP Single-Use Products for relevant applications. In applications where disposable products offer a functional advantage, medical users benefit from a comprehensive selection of disposable consumables and disposable instruments for many specialties – such as ENT, anesthesia, gastroenterology, laparoscopy, gynecology, urology, and arthroscopy – and the associated product groups.

The MTP Single-Use Products from KARL STORZ afford users and patients particularly high hygienic and functional quality. Many of these products are supplied sterile and support the diagnostic and therapeutic procedures performed with the aid of disposable products.

Highlights

Smoke Evacuation Filter Set for Single Use

The smoke evacuation filter set is used for the filtration and regulated release of smoke generated in laparoscopic procedures, reducing risks for patients and OR staff.

  • Filtration of microorganisms, particles, and toxic chemical substances
  • Filter efficiency > 99.9999% for the sample tested
  • Length 500 mm
  • Male LUER lock connector
  • Flow rate up to 8 l/min at 15 mmHg
  • Roller clamp for controlling the flow rate
  • Passive smoke evacuation
  • Product delivered sterile and ready for immediate use

 

Single-Use Tubing Sets for the ENDOMAT® SELECT

ENDOMAT® SELECT is a single roller pump for the irrigation or suction of fluids during surgical and diagnostic procedures. The pump can be equipped with various software modules, allowing interdisciplinary integration into a variety of hospital settings for indication-specific use.

Special features of the single-use tubing sets:

  • Indication-specific single-use tubing sets
  • Packaging specifies specialties of intended use
  • Tubing cassette design allows one-hand operation
  • Tubing cassettes coded such that the device only recognizes them if the corresponding software has been started on the device. Hence, the pump works only within the parameters permitted for a particular application.

The New MTP Intubation Videoendoscope FIVE S

Special Features:

  • The flexible single-use videoendoscopes can be used in conjunction with the C-MAC® monitor and are thus part of the modular C-MAC® system
  • CMOS chip and LED light source at the distal tip of the endoscope
  • Working channel of 1.2 mm for suction, the administration of oxygen and/or a local anesthetic or the introduction of medication
  • Sheath stiffness is adapted to indications in anesthesiology
  • Tube fixator at the proximal end of the sheath
  • Video and image capture as well as data storage via the C-MAC® monitor 
  • Product is sterile on delivery and is ready for immediate use

This may be of interest to you as well:

Additional information on the specialty

FIVE-S

FIVE-S

Media type:
Video, Teaser
Languages available:
D, E
Version:
2019
Material number:
1115E
Specialties:
VITOM® – An Alternative Visualization System for LEEP in the Operating Room

VITOM® – An Alternative Visualization System for LEEP in the Operating Room

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT
Version:
8.6 03-2021
Material number:
96122033E
Specialties:
Flexible Single-use Video Endoscopes – Sterile

Flexible Single-use Video Endoscopes – Sterile

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT
Version:
1.3 12-2020
Material number:
96312007E
Specialties:
MTP SINGLE-USE PRODUCTS

MTP SINGLE-USE PRODUCTS

Media type:
Catalogs
Languages available:
D, E, ES, FR, IT, RU
Version:
2.0 02-2019
Material number:
96300000E
Specialties:
MTP Single-Use Products
Scope Warmer for single use

Scope Warmer for single use

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT
Version:
1.1 10-2020
Material number:
96302002E
Specialties:
MTP Single-Use Products
Highlights Single-use Filter Sets For insufflation and smoke evacuation

Highlights Single-use Filter Sets For insufflation and smoke evacuation

Media type:
Marketing Brochures
Languages available:
D, E, ES, FR, IT, PT
Version:
3.0 07-2020
Material number:
96301000E
Specialties:
MTP Single-Use Products
UP501 S-PILOT® Tube Squeeze Valve

UP501 S-PILOT® Tube Squeeze Valve

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL
Version:
3.1 05-2020
Material number:
96116047D
Specialties:
This document is only available for registered users. Please log in.
ROTOCUT G2 Electromechanical Morcellator models 2672x RC UNIDRIVE® S III motor system model 20701020-1

ROTOCUT G2 Electromechanical Morcellator models 2672x RC UNIDRIVE® S III motor system model 20701020-1

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL
Version:
3.1 11-2019
Material number:
96116046D
Specialties:
This document is only available for registered users. Please log in.
CMOS Video Rhino-Laryngoscope SSU CMOS Video Esophagoscope SSU – for single use – REF 091330-01, 091370-01

CMOS Video Rhino-Laryngoscope SSU CMOS Video Esophagoscope SSU – for single use – REF 091330-01, 091370-01

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT, RU, CN, AR, JP, TR, US
Version:
1.4 03-2020
Material number:
97000230
Specialties:
This document is only available for registered users. Please log in.
40701620-1 UNIDRIVE® S III ENT

40701620-1 UNIDRIVE® S III ENT

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
3.1 12-2019
Material number:
96056025D
Specialties:
This document is only available for registered users. Please log in.
20701020-1 - UNIDRIVE® S III /DrillCut-X® II GYN - Shaver

20701020-1 - UNIDRIVE® S III /DrillCut-X® II GYN - Shaver

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL
Version:
3.0 10-2019
Material number:
96116040D
Specialties:
This document is only available for registered users. Please log in.