麻醉及急救外科
卡尔史托斯近年来研发的呼吸道管理系统对急救医学产生了极大的影响。特别是在治疗意料中和意料外呼吸道困难的各种疾病方面,公司推出了一系列专用器械,以创造最佳的观测条件并最大限度地降低并发症。卡尔史托斯产品丰富多样,除传统型喉镜、纤维插管镜及BONFILS后磨牙气管插管喉镜外,C-MAC® 视频喉镜更获得市场广泛青睐。作为设备核心部件,C-MAC®显示屏既可各种连接插管喉镜及C-MAC®视频喉镜,又可兼容最新的柔性插管视频内镜(FIVE)。而密闭防水的C-MAC® PM(Pocket Monitor)系统则尤为适用于临床前及移动用途。
产品推介
应用领域的其它信息
未找到与您搜索相匹配的结果
未找到与您搜索相匹配的结果

冷光源喉镜

FIVE S – 电子插管软镜 – 一次性使用 – REF 091361-01

C-MAC® S 电子喉镜片- 一次性使用 - REF 051110-01, 051111-01

吸引阀 – 一次性使用 – REF 091010-01, 091011-01, 091012-01

冷光源喉镜 • 配备细长型电池插件,高功率 LED,型号 8547 LD
Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults.
Comparison of Tracheal Intubation Conditions in Operating Room and Intensive Care Unit: A Prospective, Observational Study
人类医学
麻醉及急救外科
Anesthesiology. 2018 Aug;129(2):321-328. doi: 10.1097/ALN.0000000000002269.
Airway management in paediatric anaesthesia in Europe-insights from APRICOT (Anaesthesia Practice In Children Observational Trial): a prospective multicentre observational study in 261 hospitals in Europe
人类医学
麻醉及急救外科
Br J Anaesth. 2018 Jul;121(1):66-75. doi: 10.1016/j.bja.2018.04.013. Epub 2018 May 18.
Seeing is believing: getting the best out of videolaryngoscopy.
Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.
Diagnostic accuracy of anaesthesiologists' prediction of difficult airway management in daily clinical practice: a cohort study of 188 064 patients registered in the Danish Anaesthesia Database
人类医学
麻醉及急救外科
Anaesthesia. 2015 Mar;70(3):272-81. doi: 10.1111/anae.12955. Epub 2014 Dec 16.
Does the use of video laryngoscopy improve intubation outcomes?
人类医学
麻醉及急救外科
Ann Emerg Med. 2014 Aug;64(2):165-6. doi: 10.1016/j.annemergmed.2014.01.032. Epub 2014 Mar 11.
Videolaryngoscopy as a new standard of care
Intubation in the ICU: we could improve our practice
Practice Guidelines for Management of the Difficult Airway – Update der American Society of Anesthesiologists Task Force
Video laryngoscopy olé! Time to say good bye to direct and flexible intubation?
人类医学
麻醉及急救外科
Anaesthesist. 2012 Dec;61(12):1017-26. doi: 10.1007/s00101-012-2110-5, Springer Verlag 2012
Videolaryngoscopy allows a better view of the pharynx and larynx than classic laryngoscopy
The Storz C-MAC video laryngoscope: Description of a new device, case report, and brief case series
Contamination of laryngoscope handles
人类医学
麻醉及急救外科
J Hosp Infect. 2010 Feb;74(2):123-8. doi: 10.1016/j.jhin.2009.09.015. Epub 2010 Jan 22
Self-directed deliberate practice with virtual fiberoptic intubation improves initial skills for anesthesia residents
Comparison of the Bonfils Intubation Fibrescope versus C-MAC Videolaryngoscope
Predictors of Difficult Intubation with the Bonfils Rigid Fiberscope
Bonfils intubation fibrescope: use in simulation-based intubation training for medical students in comparison to MacIntosh laryngoscope
人类医学
麻醉及急救外科
J Emerg Med. 2016 Mar;50(3):e107-14. doi: 10.1016/j.jemermed.2015.06.070. Epub 2015 Dec 22.
Awake tracheal intubation in a patient with a supraglottic mass with the Bonfils fibrescope after failed attempts with a flexible fibrescope
Tracheal intubation with the Bonfils fiberscope in the difficult pediatric airway: a comparison with fiberoptic intubation
人类医学
麻醉及急救外科
Paediatr Anaesth. 2015 Apr;25(4):372-8. doi: 10.1111/pan.12523. Epub 2014 Sep 12.
Use of the Bonfils intubating fiberscope in a baby with a severely compromised airway
A randomized controlled comparison of the Bonfils fiberscope and the GlideScope Cobalt AVL video laryngoscope for visualization of the larynx and intubation of the trachea in infants and small children with normal airways
Clinical Uses of the Bonfils Retromolar Intubation Fiberscope
Combined technique using videolaryngoscopy and Bonfils for a difficult airway intubation
The Bonfils fiberscope: A clinical evaluation of its learning curve and efficacy in difficult airway management
Intubation Using C-MAC Video Laryngoscope During Ex Utero Intrapartum Treatment Featuring Upper Airway Neck Mass: A Case Report
人类医学
麻醉及急救外科
A A Pract. 2019 Apr 8. doi: 10.1213/XAA.0000000000001006. [Epub ahead of print]
Evaluation of performance of C-MAC® video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
C1-C2 Motion During C-MAC D-Blade Videolaryngoscopy and Endotracheal Intubation in 2 Patients With Type II Odontoid Fractures: A Case Report
人类医学
麻醉及急救外科
A A Pract. 2019 Mar 20. doi: 10.1213/XAA.0000000000001000. [Epub ahead of print]
A randomised comparison of C-MAC™ and King Vision® videolaryngoscopes with direct laryngoscopy in 180 obstetric patients
人类医学
麻醉及急救外科
Int J Obstet Anesth. 2018 Dec 29. pii: S0959-289X(18)30373-X. doi: 10.1016/j.ijoa.2018.12.008.
C-MAC® D-BLADE for awake oro-tracheal intubation with minimal mouth opening – A safe alternative to fibreoptic bronchoscope
C-MAC© videolaryngoscopy: The anaesthetic assistant's view
Evaluation of the C-MAC Miller Video Laryngoscope Sizes 0 and 1 During Tracheal Intubation of Infants Less Than 10 kg
人类医学
麻醉及急救外科
Pediatr Emerg Care. 2017 Oct 2. doi: 10.1097/PEC.0000000000001296. [Epub ahead of print]
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation: a Cochrane Systematic Review
人类医学
麻醉及急救外科
British Journal of Anaesthesia, 119 (3): 369–83 (2017), doi: 10.1093/bja/aex228 Cochrane Database Syst Rev. 2016 Nov 15;11:CD011136
Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial
Comparison of the C-MAC video laryngoscope to a flexible fiberoptic scope for intubation with cervical spine immobilization.
人类医学
麻醉及急救外科
J Clin Anesth. 2016 Jun;31:46-52. doi: 10.1016/j.jclinane.2015.12.045. Epub 2016 Mar 22.
A Randomized Clinical Trial Comparing the Standard Mcintosh Laryngoscope and the C-Mac D blade Video laryngoscope™ for Double Lumen Tube Insertion for One Lung Ventilation in Onco surgical Patients
Comparison of the C-Mac video laryngoscope with the McGrath Series 5 videolaryngoscope concerning an extremely difficult airway
Comparison of Macintosh laryngoscope and C-MAC video laryngoscope for intubation in lateral position
人类医学
麻醉及急救外科
J Anaesthesiol Clin Pharmacol. 2015 Apr-Jun; 31(2): 226–229. doi: 10.4103/0970-9185.155221
Videolaryngoscopy for teaching and supervising rigid bronchoscopy in paediatric patients
Successful use of C-Mac video laryngoscope in a child with large parapharyngeal mass
Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: a randomized, controlled comparison in patients with suspected difficult airways
Reintubation using the C-MAC videolaryngoscope. Implementation in patients with difficult airways initially managed with in situ laryngeal tubes.
人类医学
麻醉及急救外科
Anaesthesist 2012 Sep; 61(9):777-82; DOI 10.1007/s00101-012-2072-7, Springer-Verlag 2012
Randomized controlled trial comparing the McGrath videolaryngoscope with the C-MAC videolaryngoscope in intubating adult patients with potential difficult airways
Videolaryngoscopy offers advantages over classic laryngoscopy in a patient with seriously limited lip opening
人类医学
麻醉及急救外科
J Anesth. 2012 Jun;26(3):468-9. doi: 10.1007/s00540-011-1314-1. Epub 2012 Jan 12.
Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway
A randomised, controlled crossover comparison of the C-MAC videolaryngoscopy in 150 patients during routine induction of anaesthesia
First clinical evaluation of the C-MAC D-Blade videolaryngoscope during routine and difficult intubation
Learning Endotracheal Intubation Using a Novel Videolaryngoscope Improves Intubation Skills of Medical Students
Performance of the C-MAC video laryngoscope in patients after a limited glottic view using Macintosh laryngoscopy
The C-MAC Videolaryngoscope: First Experiences with a new device for videolaryngoscopy-guided intubation
人类医学
麻醉及急救外科
Anesth Analg. 2010 Feb 1;110(2):473-7. doi: 10.1213/ANE.0b013e3181c5bce5. Epub 2009 Nov 16.
Utilizing Video versus Direct Laryngoscopy to Intubate Simulated Newborns while Contained within the Incubator: A Randomized Crossover Study
Video laryngoscopy versus direct laryngoscopy for orotracheal intubation in the intensive care unit: a systematic review and meta-analysis
人类医学
麻醉及急救外科
Intensive Care Med. 2014 May;40(5):629-39. doi: 10.1007/s00134-014-3236-5. Epub 2014 Feb 21.
A review of video laryngoscopes relevant to the intensive care unit
人类医学
麻醉及急救外科
Indian J Crit Care Med. 2014 Jul;18(7):442-52. doi: 10.4103/0972-5229.136073.
Airway management in the intensive care unit
Airway management disasters in the ICU - lessons learned?
人类医学
麻醉及急救外科
Crit Care. 2012; 16(5): 162. Published online 2012 October 29. doi: 10.1186/cc11641
Out-of-hospital airway management. Five scenes of a tragedy.
Endotracheal intubation using the C-MAC(R) video laryngoscope or the Macintosh laryngoscope: a prospective, comparative study in the ICU
Comparison of video laryngoscopy versus direct laryngoscopy for intubation in emergency department patients with cardiac arrest: A multicentre study
人类医学
麻醉及急救外科
Resuscitation. 2019 Mar;136:70-77. doi: 10.1016/j.resuscitation.2018.10.005. Epub 2018 Oct 29.
C-MAC® video-laryngoscope assisted removal of pediatric upper airway foreign body via apneic technique: Two case reports
人类医学
麻醉及急救外科
SAGE Open Med Case Rep. 2019 Jan 12;7:2050313X18823088. doi: 10.1177/2050313X18823088. eCollection 2019.
Usefulness of C-MAC video laryngoscope in direct laryngoscopy training in the emergency department: A propensity score matching analysis
人类医学
麻醉及急救外科
PLoS One. 2018 Dec 12;13(12):e0208077. doi: 10.1371/journal.pone.0208077. eCollection 2018.
Use of the C-MAC Macintosh 0 Blade for Intubation of Infants in the Emergency Department
C-MAC videolaryngoscope compared with direct laryngoscopy for rapid sequence intubation in an emergency department: A randomised clinical trial
The Utility of the C-MAC as a Direct Laryngoscope for Intubation in the Emergency Department
人类医学
麻醉及急救外科
J Emerg Med. 2016 Oct;51(4):349-357. doi: 10.1016/j.jemermed.2016.05.039. Epub 2016 Jul 25.
The Use of a Video Laryngoscope by Emergency Medicine Residents Is Associated With a Reduction in Esophageal Intubations in the Emergency Department.
人类医学
麻醉及急救外科
Acad Emerg Med. 2015 Jun;22(6):700-7. doi: 10.1111/acem.12674. Epub 2015 May 20.
Comparison of the C-MAC video laryngoscope with direct Macintosh laryngoscopy in the emergency department
人类医学
麻醉及急救外科
Emerg Med Australas. 2015 Apr;27(2):119-25. doi: 10.1111/1742-6723.12358. Epub 2015 Jan 29
The C-MAC® Video Laryngoscope Is Superior to the Direct Laryngoscope for the Rescue of Failed First-Attempt Intubations in the Emergency Department.
人类医学
麻醉及急救外科
J Emerg Med. 2014 Dec 11. pii: S0736-4679(14)01124-X. doi: 10.1016/j.jemermed.2014.10.007.
A Comparison of Video Laryngoscopy to Direct Laryngoscopy for the Emergency Intubation of Trauma Patients
A Comparison of the GlideScope Video Laryngoscope to the C-MAC Video Laryngoscope (Macintosh Blade) for Intubation in the Emergency Department
人类医学
麻醉及急救外科
Ann Emerg Med 2013 Jan 29. pii: S0196-0644(12)01717-9. doi: 10.1016/j.annemergmed.2012.11.001.
A Comparison of the C-MAC Video Laryngoscope to the Macintosh Direct Laryngoscope for Intubation in the Emergency Department
Effective Use of Video Laryngoscopy in Emergencies
人类医学
麻醉及急救外科
Reprint, 5/17;33: 242-249, Georg Thieme Verlag
Impact of Video Laryngoscopy on Advanced Airway Management by Critical Care Transport Paramedics and Nurses Using the CMAC Pocket Monitor
人类医学
麻醉及急救外科
Biomed Res Int. 2015;2015:821302. doi: 10.1155/2015/821302. Epub 2015 Jun 17
Improvement in glottic visualisation by using the C-MAC PM video laryngoscope as a first-line device for out-of-hospital emergency tracheal intubation: An observational study
Out-of-hospital airway management. Five scenes of a tragedy.
Variables associated with successful intubation attempts using video laryngoscopy: a preliminary report in a helicopter emergency medical service
人类医学
麻醉及急救外科
Prehosp Emerg Care. 2012 Apr-Jun; 16(2):293-8. doi: 10.3109/10903127.2011.640764. Epub 2011 Dec 22
The C-MAC videolaryngoscope for prehospital emergency intubation
Out-of-hospital airway management in trauma patients: Experiences with the C-MAC® video laryngoscope.
Videolaryngoscopy vs. fibreoptic bronchoscopy for awake tracheal intubation: a systematic review and meta-analysis
人类医学
麻醉及急救外科
Anaesthesia. 2018 Sep;73(9):1151-1161. doi: 10.1111/anae.14299. Epub 2018 Apr 17.
The use of the C-MAC videolaryngoscope for awake intubation in patients with a predicted extremely difficult airway: case series
人类医学
麻醉及急救外科
Ther Clin Risk Manag. 2018 Mar 14;14:539-542. doi: 10.2147/TCRM.S150536. eCollection 2018