Highlights
MTP Single-Use Products
- Smoke Evacuation Filter Set for Single Use
- Single-Use Tubing Sets for the ENDOMAT® SELECT
- The New MTP Intubation Videoendoscope FIVE S
- C-MAC® S – The Video Laryngoscope for Single Use
- C-MAC® S – The Video Laryngoscope for Single Use for Pediatric Applications
- Flexible Video Endoscopes for Single Use for ENT Applications
- Single-Use HyDOME® Albarran System for Duodenoscopes
- Scope Warmer for Single Use
- CLICKline Single-Use Scissors – Simply Sharp!
- TRAPBAG Extraction Bag with Fish Trap Seal
- MiniTwin TRAPBAG
- Heatable Insufflation Tubing Set with Gas Filter for Single Use
- Extraction Bags for Laparoscopic Tissue Retrieval
- ENDOBAG Extraction Bags
- Irrigation/Suction Tubing Sets for KARL STORZ Handles
- Camera covers with elastic tip
- Bipolar Single-Use Electrodes for Applications in Urology
Smoke Evacuation Filter Set for Single Use
The smoke evacuation filter set is used for the filtration and regulated release of smoke generated in laparoscopic procedures, reducing risks for patients and OR staff.
- Filtration of microorganisms, particles, and toxic chemical substances
- Filter efficiency > 99.9999% for the sample tested
- Length 500 mm
- Male LUER lock connector
- Flow rate up to 8 l/min at 15 mmHg
- Roller clamp for controlling the flow rate
- Passive smoke evacuation
- Product delivered sterile and ready for immediate use
Single-Use Tubing Sets for the ENDOMAT® SELECT
ENDOMAT® SELECT is a single roller pump for the irrigation or suction of fluids during surgical and diagnostic procedures. The pump can be equipped with various software modules, allowing interdisciplinary integration into a variety of hospital settings for indication-specific use.
Special features of the single-use tubing sets:
- Indication-specific single-use tubing sets
- Packaging specifies specialties of intended use
- Tubing cassette design allows one-hand operation
- Tubing cassettes coded such that the device only recognizes them if the corresponding software has been started on the device. Hence, the pump works only within the parameters permitted for a particular application.
The New MTP Intubation Videoendoscope FIVE S
Special Features:
- The flexible single-use videoendoscopes can be used in conjunction with the C-MAC® monitor and are thus part of the modular C-MAC® system
- CMOS chip and LED light source at the distal tip of the endoscope
- Working channel of 1.2 mm for suction, the administration of oxygen and/or a local anesthetic or the introduction of medication
- Sheath stiffness is adapted to indications in anesthesiology
- Tube fixator at the proximal end of the sheath
- Video and image capture as well as data storage via the C-MAC® monitor
- Product is sterile on delivery and is ready for immediate use
C-MAC® S – The Video Laryngoscope for Single Use
The C-MAC® S system combines the reusable IMAGER as well as the monitor with video laryngoscopes for single use. The advantage of single-use blades over reusable blades is that the risk of cross-contamination is minimized. This effect is enhanced by the fact that the blade and handle form one continuous piece. The IMAGER features a CMOS chip as well as a LED light source that can be reprocessed at temperatures up to 65 °C.
Special Features:
- Blade and handle form one continuous piece
- For direct and indirect laryngoscopy with original MACINTOSH blade shape
- For routine clinical use and training
- Standard MACINTOSH blades in sizes 3 and 4
- Hyperangulated D-BLADE for difficult airways
- Compatible with the C-MAC® III monitor, C-MAC® PM II and C-HUB® II
C-MAC® S – The Video Laryngoscope for Single Use for Pediatric Applications
Flexible Video Endoscopes for Single Use for ENT Applications
Situations where the use of single-use endoscopes may be recommended:
- Highly infectious patients
- Clinics without in-house reprocessing departments
- Irregular use of flexible endoscopes
- Backup for reusable endoscopes
Special Features:
- The flexible single-use videoendoscopes can be used in conjunction with the C-MAC® monitor and are thus part of the modular C-MAC® system
- CMOS chip and LED light source at the distal tip of the endoscope
- Video and image capture as well as data storage via the C-MAC® monitor
- Product is sterile on delivery and is ready for immediate use
This may be of interest to you as well:
Single-Use HyDOME® Albarran System for Duodenoscopes
- The single-use module consists of a pull wire and a lever mechanism (Albarran module)
- Secure positioning of the module with just one click
- Removing and discarding the single-use module after each procedure prevents cross-contamination. Removing the module provides direct access to the Albarran channel of the endoscope to facilitate thorough brushing and flushing of the channel.
- Product is sterile on delivery and ready for immediate use
- Time-saving; no reprocessing necessary
- No wear and tear thanks to first-time applications
Scope Warmer for Single Use
For warming the scope for fog-free work
- Warmer activated to heat endoscope via a metal plate
- Suitable for all rigid endoscopes
- Available in two different sizes (12 x 20 cm and 12 x 36 cm)
- No other heat source (electricity, warm water, etc.) required
- Product is sterile on delivery and is ready for immediate use
- Two scopes can be heated in the warmer at the same time
CLICKline Single-Use Scissors – Simply Sharp!
The single-use scissor inserts can be combined with all reusable handles in the KARL STORZ CLICKLINE series. They are therefore suitable for both regular use or as a backup system.
Special Features:
- No long-term blunting of scissor blades thanks to first-time applications
- Inserts sterile-packed in individual blister packs and delivered in packages of 10 in a dispenser box
- “Single-use meets reusable”: Single-use scissors combined with reusable handles
- Color coding for the identification of single-use components
TRAPBAG Extraction Bag with Fish Trap Seal
- Each extraction bag pre-packaged in an insertion aid for insertion through a 10 mm trocar
- After the insertion aid is removed, the trocar is no longer blocked and can then be used for other instruments
- Fish trap seal prevents the leakage of tissue or fluid samples, even when bag is open
- Nitinol memory wire for opening and closing the extraction bag
- Transparent material
MiniTwin TRAPBAG
For the laparoscopic removal of lymph nodes
- Two extraction bags pre-packaged in one insertion aid: Bags can be inserted separately via a 10 mm trocar
- After the insertion aid is removed, the trocar is no longer blocked and can then be used for other instruments
- Both extraction bags feature a different design for the differentiation of tissue samples
- Fish trap seal prevents the leakage of tissue or fluid samples, even when bag is open
- Nitinol memory wire for opening and closing the extraction bag
- Transparent material
Heatable Insufflation Tubing Set with Gas Filter for Single Use
- Integrated filament for gas heating (approx. 37 °C)
- Reduces the risk of contamination between the patient and the insufflation unit
- Filter membrane hydrophobic on both sides with filter efficiency > 99.99%
- Gas flow up to 50 l/min
- Approved for the insufflator ENDOFLATOR® 50
- Product is sterile on delivery and is ready for immediate use
Extraction Bags for Laparoscopic Tissue Retrieval
Special features:
- Each extraction bag pre-packaged in an insertion aid: easy insertion through a 10 mm trocar
- Once the insertion aid is removed, the trocar is free to use with other instruments
- Memory wire for opening and closing the extraction bag
- Transparent material
- The KÖCHLI extraction bag retriever is recommended for easier retrieval of the extraction bag
- Available in 3 sizes: 200 ml, 800 ml, 1500 ml
ENDOBAG Extraction Bags
Special features:
- Each extraction bag pre-packaged in an insertion aid for insertion through a 10 mm trocar
- Once the insertion aid is removed, the trocar is free to use with other instruments
- Memory wire for opening and closing the extraction bag
- Smaller-diameter container section of the bag for straightforward ENDOBAG retrieval through the incision
- Transparent material
- Available in 2 sizes:
- Work volume 260 ml, filling volume 62 ml
- Work volume 200 ml, filling volume 53 ml
Irrigation/Suction Tubing Sets for KARL STORZ Handles
The single-use irrigation/suction tubing sets are used in combination with the reusable KARL STORZ irrigation/suction handles.
Special features:
- Single-use tubing sets reduce risk of cross-contamination
- Product delivered sterile and ready for immediate use
- Color coding allows easier differentiation between irrigation and suction tubes
- Irrigation tubing sets compatible with the pump in use can be attached to the tubing connection
Camera covers with elastic tip
Bipolar Single-Use Electrodes for Applications in Urology
The KARL STORZ product portfolio includes loops for resection, incision, en-bloc resection as well as vaporization and enucleation electrodes for the prostate, bladder and urethra.
Special Features:
- No return of current via the sheath
- Active and return electrode are totally insulated against all conductive components of the resectoscope and therefore also primarily insulated against the urethra
- No long-term wear and tear of the electrodes thanks to first-time applications
- Electrodes are sterile on delivery and are therefore ready for immediate use
- Depending on the electrodes used, various techniques can be performed with the same working element