KARL STORZ's company history is full of innovative ideas for devices that have decisively influenced the development of endoscopic procedures. This includes the ultrasonic lithotripter, the HF surgical unit with automatic cutting and coagulation current control, and the cold light source, to name just a few. The current generation of KARL STORZ devices are highly innovative as well.

These units stand out through their standardized, modular design concepts, and particularly thanks to their durable mechanics and control technology. They are operated through structured menu navigation, with newer devices featuring a touch screen. All units are designed and manufactured to meet the highest quality and safety requirements and undergo strict safety testing before delivery.

The KARL STORZ unit portfolio includes:

  • Insufflators
  • Suction and irrigation systems
  • Units for high frequency surgery
  • Laser systems
  • Motor systems
  • Lithotripsy systems

Highlights

ENDOMAT® SELECT – The Choice is Yours

ENDOMAT® SELECT is an interdisciplinary roller pump for the irrigation or suction of fluids during surgical and diagnostic procedures. Depending on customer preferences, the pump can be equipped with various software packages so that it can be used for either individual or multiple disciplines.

Benefits at a glance:

  • Cost-efficient pump as modular design supports basic functionality across various fields of application
  • Easy handling thanks to tubing set for single hand control
  • Safe use thanks to tubing set recognition
  • Seamless integration into existing systems
  • Software allows fields of application to be expanded at any time

ENDOFLATOR® 50

Insufflation with gas heater

  • Gas flow up to 50 l/min in combination with KARL STORZ HICAP® trocars
  • Gas heating to body temperature
  • With two insufflation modes for high flow and pediatric applications
  • Pediatrics mode: small adjustment increments in the lower output range as well as safety limits for pressure and flow
  • Used in transanal treatment and endoscopic vessel harvesting
  • Compatible with S-PILOT® – the solution for your surgical smoke management

S-PILOT® – modular smoke evacuation system

As an early pioneer in laparoscopy, KARL STORZ has consistently worked to advance the state of the art. A great example is the S-PILOT® modular smoke evacuation management system, with in-line filtration and options for both active and passive applications. Recent guidance from SAGES and EAES recommends “For MIS procedures, use of devices to filter released CO2 for aerosolized particles should be strongly considered”.
While KARL STORZ has not specifically tested the use of KARL STORZ smoke evacuation devices and SARS-CoV-2, there are data on KARL STORZ filters and its effectiveness against other bacteria and viruses.    
The filter efficiency of KARL STORZ filters was tested using the most common test methods with microorganisms known as “Virus Filtration Efficiency (VFE)” and “Bacterial Filtration Efficiency (BFE)”. These types of tests are considered to be the most similar to clinical scenarios. A test aerosol with a mean particle size of 3 +/- 0.3 µm and a virus bacteriophage ɸX174 of 0.027 µm (at VFE) or bacteria Staphylococcus aureus (at BFE) were used. Test results confirmed a filter efficiency of more than 99.9999 %.1,2
The Most Penetrating Particle Size is typically in a range of 0.1-0.3 µm. These particles are the most difficult to trap by the filter. The test aerosol DEHS (= Di-2-Ethylhexyl-Sebacat) with a size of 0.3 µm was therefore used for non-microbiological tests. A filter efficiency of more than 99.9994 % was achieved.3

Contact your local KARL STORZ representative for a solution that meets your individual needs or for more details regarding the smoke evacuation portfolio available.
The S-PILOT® with in-line filtration is part of the extensive array of KARL STORZ products designed in consultation with active laparoscopic surgeons. The complete repertoire covers the full range of diagnostic and surgical laparoscopic procedures for adult and pediatric patients. 
 

1 Nelson Laboratories Inc., Salt Lake City, USA: “Virus Filtration Efficiency Test (VFE) at an Increased Challenge Level” Lab. No. 846021-S01, 07 Dec. 2015 (internal reference: SAP ID 300000338072).

2 Nelson Laboratories Inc., Salt Lake City, USA: “Bacterial Filtration Efficiency Test (BFE) at an Increased Challenge Level” Lab. No. 846022-S01, 02 Dec. 2015 (internal reference: SAP ID 300000338073).

3 GVS Filter Technology UK, Lancashire LA3 3EN, UK: Activity Report REP: 0698/16, 21. January 2016 (internal reference: SAP ID 300000351254).

Additional information on the specialty

COR – The new equipment cart from KARL STORZ

COR – The new equipment cart from KARL STORZ

Media type:
Video, Product Film
Languages available:
D, E
Version:
2016
Material number:
849E
Specialties:
Units
Mounting a Monitor Swivel Arm to a COR Equipment Cart

Mounting a Monitor Swivel Arm to a COR Equipment Cart

Media type:
Video, Product Film
Languages available:
D, E
Version:
2016
Material number:
893E
Specialties:
Units
COR – At the heart of your OR!

COR – At the heart of your OR!

Media type:
ENDOWORLD®
Languages available:
D, E, ES, IT, PT, RU
Version:
2.1 09-2020
Material number:
96212018E
Specialties:
LAPAROSCOPY IN SURGERY, GYECOLOGY, UROLOGY

LAPAROSCOPY IN SURGERY, GYECOLOGY, UROLOGY

Media type:
Catalogs
Languages available:
D, E, ES, FR, IT, US
Version:
8.0 02-2016
Material number:
96110000U
Specialties:
Highlights ENDOMAT® SELECT

Highlights ENDOMAT® SELECT

Media type:
Marketing Brochures
Languages available:
D, E, ES, IT, PT, US
Version:
3.0 11-2019
Material number:
97321003U
Specialties:
Units
UP501 S-PILOT® Tube Squeeze Valve

UP501 S-PILOT® Tube Squeeze Valve

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL
Version:
3.1 05-2020
Material number:
96116047D
Specialties:
This document is only available for registered users. Please log in.
UH 400/400 U/401/401 U High frequency surgical unit AUTOCON® III 400

UH 400/400 U/401/401 U High frequency surgical unit AUTOCON® III 400

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, US
Version:
3.1 11-2019
Material number:
96206584U
Specialties:
This document is only available for registered users. Please log in.
28340720-1 ARTHROPUMP® POWER

28340720-1 ARTHROPUMP® POWER

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
4.1 09-2019
Material number:
96156010D
Specialties:
This document is only available for registered users. Please log in.
UP 210 ENDOMAT® SELECT

UP 210 ENDOMAT® SELECT

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, US
Version:
4.1 05-2019
Material number:
96116049U
Specialties:
This document is only available for registered users. Please log in.
UP 210 ENDOMAT® SELECT

UP 210 ENDOMAT® SELECT

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL, US
Version:
4.1 05-2019
Material number:
96116049D
Specialties:
This document is only available for registered users. Please log in.
UP410 UROMAT E.A.S.I®

UP410 UROMAT E.A.S.I®

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL
Version:
4.0 01-2019
Material number:
96136021D
Specialties:
This document is only available for registered users. Please log in.
High-Speed micromotor Model 20712033

High-Speed micromotor Model 20712033

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT, RU, US
Version:
2.0 10-2018
Material number:
96056382USCA
Specialties:
This document is only available for registered users. Please log in.
26432020-1 Thermoflator®

26432020-1 Thermoflator®

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
5.2 10-2018
Material number:
96116011D
Specialties:
This document is only available for registered users. Please log in.
20330320-1 - ENDOMAT® LC (from serial number 2000)

20330320-1 - ENDOMAT® LC (from serial number 2000)

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
3.1 09-2018
Material number:
96116039D
Specialties:
This document is only available for registered users. Please log in.
UI500 ENDOFLATOR® 50

UI500 ENDOFLATOR® 50

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU, PL, SE, US
Version:
3.0 12-2017
Material number:
96116045U
Specialties:
This document is only available for registered users. Please log in.
20302020-1 EQUIMAT®

20302020-1 EQUIMAT®

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT
Version:
4.0 01-2018
Material number:
96126001D
Specialties:
This document is only available for registered users. Please log in.
40150020 Stroboscope KARL STORZ µ-PULSAR

40150020 Stroboscope KARL STORZ µ-PULSAR

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
2.0 01-2018
Material number:
96056017D
Specialties:
This document is only available for registered users. Please log in.
Disposable hook electrode for monopolar coagulation Model: 27030 EL

Disposable hook electrode for monopolar coagulation Model: 27030 EL

Media type:
Product Package Leaflet
Languages available:
D, E, ES, FR, IT, PT
Version:
2.0 10-2017
Material number:
96136309D
Specialties:
This document is only available for registered users. Please log in.
26331020-1 HAMOU® ENDOMAT®

26331020-1 HAMOU® ENDOMAT®

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
5.0 10-2017
Material number:
96116008D
Specialties:
This document is only available for registered users. Please log in.
27750220-1 CALCULASE II

27750220-1 CALCULASE II

Media type:
User Handbooks
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
2.0 11-2017
Material number:
96136015D
Specialties: