Navigation

Arthroscopy and Sports Medicine

Joints connect bones to each other and provide the body with agility and stability. Obesity, misalignment, physical inactivity as well as sports injuries can lead to joint problems as well as restricted movement and pain.

Many minimally invasive techniques can now be performed in joint surgery thanks to modern arthroscopy. The product range from KARL STORZ covers endoscopic instrument sets and implants for treatment of the shoulder, elbow, hip and knee joints as well as the wrist, interphalangeal and ankle joints.

In cooperation with renowned physicians, KARL STORZ was able to develop innovative products and techniques for, among others, meniscal refixation, cruciate ligament reconstruction, reconstruction of shoulder instability as well as hip arthroscopy.

Furthermore, KARL STORZ offers an appropriate portfolio of implants for arthroscopic reconstructive procedures. This segment includes both titanium, Peek and bioresorbable implants such as interference screws, suture anchors and fixation buttons.

Highlights

SmartMex®

Interested? Get Product details and quotes in our Online Catalog

Specialist advice Specialist advice

Known lesion - new approach

The new SmartMex® all-inside meniscus refixation system from KARL STORZ allows easy
access to the joint to repair tears in the peripheral region and the red-white zone. The customary all-inside technique works on the principle of punching through the meniscus in order to place the implant. With the SmartMex® system, work is less traumatic as the meniscus is dilated with the implant diameter.

  • Less traumatic
  • Constant pressure distribution
  • Knotless and self-blocking system
  • Calibrated handle and stiff shaft

QuadriCut®

Interested? Get Product details and quotes in our Online Catalog

Specialist advice Specialist advice

The quadriceps tendon is used in cruciate ligament revision surgery and, more and more frequently, for the primary reconstruction of the anterior (ACL) and posterior (PCL) cruciate ligaments. The quadriceps tendon has also emerged as an ideal graft source for the reconstruction of the medial patellofemoral ligament (MPFL).

In order to provide fast and safe tendon harvesting, a special tendon harvesting system has been developed featuring the following properties:

  • Safe and easy subcutaneous tendon harvesting
  • Defined harvesting depth

The instrument set also enables quadriceps tendon harvesting for the anatomical reconstruction of the medial patellofemoral ligament (MPFL). One of the benefits of this technique is that it allows implant- and tunnel-free fixation to the patella.

 

RICHTER POWERFIX® – Bioinert PEEK Implants for Cruciate Ligament Reconstruction

Interested? Get Product details and quotes in our Online Catalog

Specialist advice Specialist advice

POWERFIX® PEEK interference screws, made from PEEK-OPTIMA®, provide another innovation that complements the KARL STORZ implant portfolio. A highlight of the screw design is the availability of femoral reverse-thread interference screws which prevent luxation of the graft in the anterior direction during ACL reconstruction of the right knee. The double-threaded screw design makes it possible to insert the screw with just a few turns of a screwdriver that accommodates all screw sizes. 

PEEK-OPTIMA® implant material features the following properties:

  • High mechanical stability
  • Excellent biocompatibility
  • Inert, non-resorbable PEEK

The POWERFIX® interference screws made of PEEK-OPTIMA® are radiolucent and thus allow optimal monitoring of the healing process by means of X-rays, CT or MRI without creating artefacts.

Additional information on the specialty

SHOULDER PRO® Suture Forceps – Effective Suture Management in Shoulder Arthroscopy

SHOULDER PRO® Suture Forceps – Effective Suture Management in Shoulder Arthroscopy

Media type:
Video, Product Film, Teaser
Languages available:
E
Version:
2018
Material number:
1076E
Specialties:
Arthroscopy and Sports Medicine
IMAGE1 S™ 4U – mORe than a camera

IMAGE1 S™ 4U – mORe than a camera

Media type:
Video, Teaser
Languages available:
E
Version:
2019
Material number:
1065E
Specialties:
The Shoulder: Anatomical Knowledge Update

The Shoulder: Anatomical Knowledge Update

Media type:
Video, Surgical Film
Languages available:
D, E
Version:
2009
Material number:
705E
Specialties:
Arthroscopy and Sports Medicine
SILCUT® PRO – Experience meets Innovation

SILCUT® PRO – Experience meets Innovation

Media type:
Video, Product Film, Teaser
Languages available:
E
Version:
2018
Material number:
1190E
Specialties:
Arthroscopy and Sports Medicine
SILCUT® PRO – Experience meets Innovation

SILCUT® PRO – Experience meets Innovation

Media type:
Video, Product Film, Teaser
Languages available:
E
Version:
2018
Material number:
1073E
Specialties:
Arthroscopy and Sports Medicine
ENDOCAMELEON® – Change your Viewing Angle, not your Endoscope

ENDOCAMELEON® – Change your Viewing Angle, not your Endoscope

Media type:
Marketing Flyer
Languages available:
D, E, ES, FR, IT
Version:
1.2 03-2021
Material number:
96151006E
Specialties:
Arthroscopy and Sports Medicine
Highlights Basic Instruments for Wrist Arthroscopy

Highlights Basic Instruments for Wrist Arthroscopy

Media type:
Marketing Brochures
Languages available:
D, E
Version:
1.0 04-2021
Material number:
96151050E
Specialties:
Arthroscopy and Sports Medicine
SilCut® PRO and SilGrasp® PRO – The perfect bite

SilCut® PRO and SilGrasp® PRO – The perfect bite

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
7.3 04-2021
Material number:
96152044E
Specialties:
Arthroscopy and Sports Medicine
TRAINERS AND SIMULATORS

TRAINERS AND SIMULATORS

Media type:
Catalogs
Languages available:
D, E, ES, FR, IT, RU
Version:
1.0 02-2018
Material number:
96010001E
Specialties:
KARL STORZ Arthroscope Sheaths for a fast and secure telescope-sheath connection

KARL STORZ Arthroscope Sheaths for a fast and secure telescope-sheath connection

Media type:
ENDOWORLD®
Languages available:
D, E, ES, FR, IT, PT, RU
Version:
6.1 02-2021
Material number:
96152043E
Specialties:
Arthroscopy and Sports Medicine

Your search yielded no results.

Arthroscopic reconstruction of the anterolateral bundle of the posterior cruciate ligament in single-bundle technique with autologous hamstring grafts

Human Medicine

Arthroscopy and Sports Medicine

Petersen W, Zantop T.

Oper Orthop Traumatol. 2010 Oct;22(4):354-72.

Minimally Invasive Acromioclavicular Joint Reconstruction (MINAR)

Human Medicine

Arthroscopy and Sports Medicine

Petersen W, Wellmann M, Rosslenbroich S, Zantop T.

Oper Orthop Traumatol. 2010 Mar;22(1):52-61.

Standardized cartilage biopsies from the intercondylar notch for autologous chondrocyte implantation (ACI)

Human Medicine

Arthroscopy and Sports Medicine

Niemeyer P, Pestka JM, Kreuz PC, Salzmann GM, Köstler W, Südkamp NP, Steinwachs M.

Knee Surg Sports Traumatol Arthrosc. 2010 Aug;18(8):1122-7. Epub 2010 Mar 27.

Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique

Human Medicine

Arthroscopy and Sports Medicine

Lenschow S, Herbort M, Strässer A, Strobel M, Raschke M, Petersen W, Zantop T.

Arch Orthop Trauma Surg. 2011 Aug;131(8):1067-72. Epub 2011 Feb 18.